Answer:
Attached below
Explanation:
PWM signal source has 1 KHz base frequency
Analog filter : with time constant = 0.01 s
low pass transfer function = [tex]\frac{1}{0.01s + 1 }[/tex]
PWM duty cycle is a constant block
Attached below is the design and simulation into Simulink at 25% , 50% and 100% respectively